Question no:1
You are on site and a remote administrator wants to verify that a failed internal disk in a Sun Fire V440 is ready to replace. What two things should you do to confirm that the disk is ready for replacement? (Choose two.)
A. Check that the amber LED beside the disk drive slot is on.
B. Check that the blue LED beside the disk drive slot is blinking.
C. Make sure no LEDS are on.
D. Issue the RSC command showenvironment.
E. Check that the blue LED beside the disk drive slot is on.
Answer: D,E


Question no:2
A customer's Sun Fire V240 crashed, but no core dump file was saved because the utility to save a core dump was incorrectly configured. What command should you use to change the configuration to allow a core file to be saved automatically in the future?
A. dumpcore
B. dumpadm
C. vmcore
D. coresav
Answer: B


Question no:3
After completing an install on a Sun Fire V440, you need to place it into production. What two methods can you use to power on the server from the front panel? (Choose two.)
A. Ensure the power supply Standby/AC Available LED is green; Turn the system control keyswitch to the tandby position; Depress the power button for 4 seconds.
B. Ensure the power supply Standby/AC Available LED is green; Turn the system control keyswitch to the ormal position; Momentarily depress the power button.
C. Ensure the power supply Standby/AC Available LED is green; Turn the system control keyswitch to the iagnostic position; Momentarily depress the power button.
D. Ensure the power supply Standby/AC Available LED is green; Turn the system control keyswitch to the knocked position; Momentarily depress the power button.
E. Ensure the power supply Standby/AC Available LED is green; Turn the system control keyswitch to the knocked position; Depress the power button for 4 seconds.
Answer: B,C


Question no:4
A customer has a Sun Fire V240 Server that experienced a crash last weekend. A core dump was saved and consists of two files: unix.0 and vmcore.0. You need to pack these files in a tar.gz archive, for upload. How can you create the archive?
A. gzip unix.0 vmcore.0 | tar cf archive.tar.gz
B. gzcat unix.0 vmcore.0 | tar cf - archive.tar.gz
C. tar cf - archive.tar.gz unix.0 vmcore.0 | gzip
D. tar cf - unix.0 vmcore.0 | gzip > archive.tar.gz
Answer: D


Question no:5
A customer informs you that their Sun Fire V480 crashed and will not boot. They are getting an error message, but it scrolls off screen too rapidly to report it. What command should you issue in an attempt to isolate the boot problem to hardware or software?
A. setenv diag-level max
B. boot cdrom -sv
C. test-network
D. boot default-device
Answer: B


Question no:6
A customer has a Sun Fire V250 and wants you to add a SCSI controller PCI card. After you have physically added the card, you want to check if the new SCSI controller is recognized. What OpenBoot command should you use to recognize the controller?
A. probe-scsi-all
B. probe-pci-bus
C. probe-pci-slots
D. probe-scsi
Answer: A


Question no:7
A customer has had a failure on a Sun Fire V440 currently in production. They are not sure yet what has failed and the machine is still up and running. The customer wants to know what the implications are for downtime under various possible repair scenarios. What two FRUs can you replace while Solaris is running? (Choose two.)
A. CPU fan tray
B. CPU/memory module
C. PCI card
D. Disk
E. Power supply
Answer: D,E


Question no:8
You have finished physically adding a CPU to a Sun Fire V440 and need to verify that the number of CPUs physically installed corresponds to the number of CPUs seen at the OBP level. How can you check how many CPUs are seen at the OBP level?
A. show-cpus
B. list-cpus
C. show-devs
D. upa-list
Answer: C


Question no:9
You are installing a Sun Fire V440, which is NOT installed with a Pre-Boot Image. What two methods could you use to install the system? (Choose two.)
A. sc> console
B. ok reset-all
C. ok boot net - install
D. ok boot cd -install
E. ok boot cdrom - install
Answer: C,E

310-878

 

 

 

Braindumps Real exam questions and verified answers - 100% passing guarantee - cheap prices.

 

Braindumps and Exams - Instant download real exam questions - Passing guarantee.

Follow us on FaceBook
Braindumps on Facebook
 
 
 
 
 

CheckPoint

Linux

Novell

DB/2

Network Appliance

EC-Council

Nortel

McAfee

Juniper

ISACA

PMI

Sybase

EMC

HDI

SNIA

ISC

Sair

IBM

Lotus

Exam Express

3COM

BICSI

DeLL

Enterasys

Extreme Networks

Guidance Software

Computer Associates

Network General

SAS Institute

Alcatel Lucent

SeeBeyond

TruSecure

Polycom

Hyperion

Hitachi

Nokia

Fortinet

Vmware

Fujitsu

Tibco

Intel

PostgreSQLCE

BusinessObjects

RESSoftware

BlackBerry

AccessData

ICDL

Isilon

SAP

The Open Group

ACSM

Altiris

Avaya

Cognos

F5

Genesys

SDI

ACI

ASQ

Google

H3C

HIPAA

HRCI

SOA

IIBA

Zend