Casey
 
 

 

Braindumps of 000-365
i5 iSeries LPAR Technical Solutions V5R3

Exam Questions, Answers, Braindumps (000-365)

This braindump is provided with ratings from different students. I used www.examcheats.net study material and the exam was not a problem for me.

Q: 1 Company.com has three AS/400 systems: a Model 720, a Model 270, and a Model 170, all are on V5R3. They want to consolidate all the servers into an eServer i5 520 with three partitions. The basic configurations include:
A Model 720 with:
.1 FC #2722 twinax
.2 FC #2745 two-line communications
.1 FC #2838 Ethernet
A Model 270 with:
.1 FC #4746 Twinax card
A Model 170 with:
.1 FC #2721 Twinax / communications card
.FC #2838 Ethernet
. FC #2850 IXS
Which of the following is a list of communications and LAN features that can be migrated to the new i5 520?
A. FC #2722, #2745, #4746
B. FC #2745, #2838, #4746
C. FC #2722, #2745, #2838, #4746
D. FC #2745, #2838, #4746, #2850
Answer: B

Q: 2 Company.com has an eServer i5 520 with a #0595 running with a total of 8 drives in disk bay slots 1-4 and 7-10. The system is being partitioned and the disk drives in the #0595 are being set up for the new partition. After IPLing the partition from CD, the Install Licensed Code option fails with a message that "No valid load source disk is available." Stand-alone DST shows the disk IOA and drives. Which of the following is the most likely cause of the problem?
A. The disk IOA must be in a slot adjacent to the IOP.
B. Use the HMC to set the SCSI address for the load source drive.
C. The disk drives must be in consecutive disk bays starting with bay 1.
D. One of the disk bays must have the connector cable moved to IOA port 0.
Answer: D

Q: 3 Company.com wants to move memory from an OS/400 partition to a Linux partition each night.
Which of the following procedures will accomplish this task?
A. Use SST to move the memory features to the Linux partition.
B. Use Advanced Job Scheduler to schedule the dynamic memory move.
C. Shut down the Linux partition, move the memory and reboot the Linux partition.
D. Use Management Central - Scheduled Tasks to schedule the move between the endpoint partitions.
Answer: C

Q: 4 An iSeries has three partitions. The primary and one secondary are at V5R1, the other secondary is at V4R5. An external switchable DVD and QIC tape are required. A failure occurs when installing the V4R5 partition from CD with the DVD-RAM drive. Which of the following is the cause?
A. The DVD-RAM cannot read CD media.
B. The DVD-RAM is not supported at V4R5 from the distribution media.
C. The tape drive must be the first in the daisy chain on the magnetic media controller.
D. The V4R5 media should be virtualized on the primary partition and loaded from the primary to the secondary.
Answer: B

Q: 5 Company.com is planning to consolidate the following systems onto a single eServer i5 LPAR system with one partition for each migrated system. The existing tape drives are also listed:
. i820 with 3590-E11 and 3581-L23 tape drives
.iSeries 720 with 3580-H13 tape drive
.iSeries 170 with 7208-345 tape drive
.RS/6000 system with 3580-H11
The i5 LPAR system will also have a Linux partition. The backup requirements are:
. Any i5/OS partition should have access to each of the tape drive types (3590, LTO, 8mm);
.the AIX and Linux partitions only require LTO access;
.the AIX and Linux partitions should be able to perform file level backups; and
. the number of tape drives and tape I/O adapters should be minimized.
What is the minimum number of tape I/O adapters required in the i5 system?
A. 3
B. 4
C. 5
D. 6
Answer: B

Q: 6 Company.com with a V4R5 partition on a Model 720 system wants to connect to a Fibre Channel attached IBM 2105-F10 (SHARK) Enterprise Storage Server. Which of the following is the appropriate solution?
A. Upgrade to an i8xx system, upgrade OS/400 in that partition to V5R3 and add an FC #2766
PCI Fibre Channel Disk Adapter to that partition.
B. Upgrade OS/400 in that partition to V5R3 and add an FC #2766 PCI Fibre Channel Disk
Adapter to that partition on the Model 720.
C. Upgrade to an i8xx system running V5R3 in the primary partition and add an FC #2766 PCI
Fibre Channel Disk Adapter to the V4R5 partition.
D. Add an FC #2766 PCI Fibre Channel Disk Adapter to that partition on the Model 720.
Answer: A

000-365


 

 

Braindumps Real exam questions and verified answers - 100% passing guarantee - cheap prices.

 

Free brain dumps Braindumps, notes, books for free

 

Braindumps and Exams - Instant download real exam questions - Passing guarantee.

Follow us on FaceBook
Braindumps on Facebook
 
 
 
 
 

CheckPoint

Linux

Novell

DB/2

Network Appliance

EC-Council

Nortel

McAfee

Juniper

ISACA

PMI

Sybase

EMC

HDI

SNIA

ISC

Sair

IBM

Lotus

Exam Express

3COM

BICSI

DeLL

Enterasys

Extreme Networks

Guidance Software

Computer Associates

Network General

SAS Institute

Alcatel Lucent

SeeBeyond

TruSecure

Polycom

Hyperion

Hitachi

Nokia

Fortinet

Vmware

Fujitsu

Tibco

Intel

PostgreSQLCE

BusinessObjects

RESSoftware

BlackBerry

AccessData

ICDL

Isilon

SAP

The Open Group

ACSM

Altiris

Avaya

Cognos

F5

Genesys

SDI

ACI

ASQ

Google

H3C

HIPAA

HRCI

SOA

IIBA

Zend